Aluminium Alloy Conductor XLPE Insulated Power Cable 3 Core NA2XS2Y / NA2XS(F)2Y / NA2X(FL)2Y
GB/T 12706.1,IEC 60502-1
Voltage Rating Uo/U:12/20(24)kV
Maximum operating temperature of conductor:+90℃
Operating ambient temperature: -15℃~+55℃
Cable laying temperature:Not less than 0℃(When the ambient temperature is below 0℃, the cable should be preheated.)
Minimum Bending Radius: Single Core 15D Three Core 12D (D is the actual outer diameter of the cable)
Specs | Conductor diameter | Outer thickness of insulation | Approx outer diameter of cable | Approx cable weight |
| Specs | Conductor diameter | Outer thickness of insulation | Approx outer diameter of cable | Approx cable weight |
1×35 | 6.6±0.2 | 20.0 | 27.8 | 965 | 3×35 | 6.6±0.2 | 20.0 | 54.7 | 3330 | |
1×50 | 7.6±0.2 | 21.0 | 28.8 | 1066 | 3×50 | 7.6±0.2 | 21.0 | 57.2 | 3729 | |
1×70 | 9.2±0.2 | 22.6 | 30.6 | 1203 | 3×70 | 9.2±0.2 | 22.6 | 60.8 | 4182 | |
1×95 | 10.9±0.2 | 24.3 | 32.3 | 1340 | 3×95 | 10.9±02 | 243 | 64.8 | 4713 | |
1×120 | 12.2±0.2 | 25.6 | 33.8 | 1483 | 3×120 | 12.2±0.2 | 256 | 67.9 | 5214 | |
1×150 | 13.6±0.2 | 27.0 | 36.5 | 1955 | 3×150 | 13.6±0.2 | 27.0 | 71.2 | 5730 | |
1×185 | 15.2±0.2 | 28.6 | 38.2 | 2164 | 3×185 | 15.2±0.2 | 286 | 75.1 | 6434 | |
1×240 | 17.4±0.2 | 30.8 | 40.6 | 2455 | 3×240 | 17.4±0.2 | 30.8 | 81.6 | 8171 | |
1×300 | 19.5±0.2 | 32.9 | 43.1 | 2773 | 3×300 | 19.5±0.2 | 329 | 86.5 | 9175 | |
1×400 | 220±0.2 | 35.4 | 45.7 | 3217 | 3×400 | 22.0±0.2 | 354 | 92.5 | 10735 | |
1×500 | 24.8±0.2 | 39.0 | 49.7 | 3750 | 3×500 | 24.8±0.2 | 39.0 | 100.8 | 12512 | |
1×630 | 282±0.2 | 42.4 | 53.4 | 4360 | 3×630 | 28.2±0.2 | 42.4 | 108.7 | 14530 | |
1×800 | 34.0±0.2 | 48.2 | 59.4 | 5192 |
|
|
|
| |
Pipe laying, trench laying, tunnel laying, vertical shaft and bridge laying, etc.
Q1: How to select proper conductor size?
A: Follow these steps:
Calculate max current (IEC 60228)
Verify short-circuit withstand (IEC 60949)
Check voltage drop (≤3% for power lines)
Standard sizes: 1.5mm² to 6mm² (18-12 AWG)
Q2: What's the flame retardancy standard for NYBY/NYRY?
A: Must pass:
• IEC 60332-1 (vertical flame)
• IEC 61034-2 (smoke density <60%)
• IEC 60754-1 (halogen content <5%)
Q3.Are you a factory or trading company?
A3: We are a manufacturer.
Q4:How to get a free sample?
A4.Ofcourse,we could provide free samples and you charge the shipping cost
Q5. How long delivery time?
A5.It usualy take 7-10days for sample order and 25-30days for big order.
Q6.What is your payment term?
A5: Our paymen term is usualy T/T30% in advanced,the balance before picking up the goods